Several methods have been recommended in the literature for the radiochemical purity control of 99mTc-mertiatide (MAG-3, mercaptoacetyltriglycine) radiopharmaceutical. This study aimed to compare these miniaturized chromatographic systems to verify their true usefulness and to determine the best way to quantify the radiochemical purity of this radiopharmaceutical, which is used in nuclear medicine for dynamic renal imaging for purposes of diagnosing the problems in kidneys. Instant Thin Layer Chromatography (ITLC) silica gel and Paper Chromatography using different solvents in different supports are analyzed. The chromatographic systems were: ITLC-SG, Whatman S&S 2589C, Whatman 4 (as support phase) in Acetone, NaCl, MEK, Absolute Alcohol, Ethyl Acetate:MEK 3:2, Acetonitrile 50% (as mobile phase). ITLC-SG was found to be the best support for these miniaturized chromatographic methods because it saves considerable time, fits quite well in the nuclear medicine department’s daily routine production, and meets the labelling criteria formulated by the manufacturer.
  1. J. Mallol, C. Bonino, “Comparison of radiochemical purity control methods for 99Tc m radiopharmaceuticals used in hospital radiopharmacies,” Nucl. Med. Commun., vol 18, no. 5, pp. 419 – 422, May 1997.
    DOI: 10.1097/00006231-199705000-00006
    PMid: 9194083
  2. B. Daci, E. Bylyku, D. Prifti, S. Malja, “Evaluation of two chromatographic methods for radiochemical purity of 99mTc-HMPAO radiopharmaceutical,” in Proc. 7th Int. Conf. Ecosystems (ICE 2017), Tirana, Albania, 2017.
  3. F. J. Van Hemert, H. van Lenthe, K. J. M. Schimmel, B. L. F. van Eck-Smit, “Preparation, radiochemical purity control and stability of 99mTc-mertiatide (Mag-3),” Ann. Nucl. Med., vol 19, no. 4, pp. 345 - 349, Jun. 2005.
    DOI: 10.1007/BF02984631
    PMid: 16097648
  4. C. Decristoforo, R. Siller, F. Chen, G. Riccabona, “Radiochemical purity of routinely prepared 99Tcm radiopharmaceuticals: a retrospective study,” Nucl. Med. Commun., vol 21, no. 4, pp. 349 – 354, Apr. 2000.
    DOI: 10.1097/00006231-200004000-00009
    PMid: 10845223
  5. S. Seetharaman, J. R. Ballinger, M. H. Sosabowski, “Simplified method for determining the radiochemical purity of 99mTc-MAG-3,” J. Nucl. Med. Technol., vol. 34, no. 3, pp. 179 – 183, Sep. 2006.
    PMid: 16951288
  6. B. Daci et al., “Comparative evaluation of the techniques for radiochemical control of 99mTc-MIBI,” Asian J. Chem., vol. 22, no. 9, pp. 7031 – 7038, Jul. 2010.
    Retrieved from: https://asianpubs.org/index.php/ajchem/article/view/11945/11926
    Retrieved on: Mar. 20, 2023